Three Phase Voltage Monitoring Relays

Three Phase Multifunction Voltage Sensitive Relays are designed for protecting three phase voltage equipment from impermissible circuit voltage surges, phase breaks, phase imbalance, phase adherence, and phase sequence violation. The relays are effectively utilized for protection of refrigerating, compressor, air-conditioning, and other equipment with electric motor loads. Also used in devices that require continuous monitoring of circuit voltage quality, availability and phase content, e.g. in automatic transfer schemes.

All voltage monitoring relays have the resetting ratio (hysteresis) of about 5V. The effective range of our relays is 30-150% of rated voltage. In case of extreme undervoltage and voltage spikes, the relay tripping acceleration is activated. The voltage monitoring relays provide for automatic load energizing after voltage parameters recovery within predetermined time relay. The relays are compact in size and weight. All relays are mounted onto standard DIN-rail.

Th? voltage sensitive relays are connected parallel to load and control the magnetic starter coil; thus the use of voltage-sensitive relays is practically independent of the load wattage. The voltage monitoring relay outputs have two groups of independent contacts (one pair of contacts is normally closed, and the other one – normally open), switching load up to 5A.

Three Phase Voltage Monitoring Relays

Three Phase Voltage Monitoring Relays
  • Three Phase Voltage Monitoring Relays
Ask For Price

Product Details:

Minimum Order Quantity1 Piece
Voltage TypeAC
Voltage (V)400 - 415 V
Number of Poles3 Pole, 4 Pole
ApplicationThree phase voltage monitoring relay, Protection of three phase load
Current (Amps)5A @ 250 V AC

RNPP-311M voltage monitoring relay is designed for protection of three phase loads against major types of mains faults, as:


  • RMS voltage reaching beyond admissible thresholds - over and under voltage
  • Phase loss or Single phasing
  • Phase sequence order violation or reverse phase sequence
  • Phase coincidence or shorting of two or more phases
  • Phase Imbalance or asymmetry

 

The device performs monitoring of the main circuit parameters and de-energizes (trip) load when the parameters fall beyond specified boundaries.

 

The front panel LEDs display the following:

 

  • Presence of true RMS voltage in the mains
  • Load status (On/Off)
  • Type of fault


Adjustment potentiometers allow for setting:


  • Tripping threshold for the minimum/the maximum voltage, (% of the rated voltage)
  • Time delay for load re-energizing (reset) after the circuit parameters recovery
  • Tripping time delay for load de-energizing (trip) in case of all circuit voltage faults


With DIP switches on the device’s front panel the user can select the type of circuit monitored 400 / 415V, and turn on/off monitoring of the following circuit parameters:


  • Phase sequence
  • Phase imbalance or asymmetry
  • Under voltage
  • Over voltage

 

Corresponding combinations of the RNPP-311M switches allow for functioning in various modes:


  • Mode of circuit voltage comprehensive monitoring
  • Minimum/the maximum voltage monitoring mode
  • Minimum voltage monitoring mode
  • Maximum voltage monitoring mode
  • Phase presence monitoring mode
  • Phase sequence violation and phase coincidence monitoring mode
  • Phase imbalance monitoring mode; and other modes

 

The phase availability monitoring function is maintained in any position of the switches, including OFF position. The feature of 24V DC online power supply is available (optional).

 

Documentation for this device

Request
Callback


Additional Information:

  • Item Code: RNPP-311M
  • Port of Dispatch: New Delhi
Yes! I am Interested
View PDF

Three Phase Voltage Monitoring

Three Phase Voltage Monitoring
  • Three Phase Voltage Monitoring
Ask For Price

Product Details:

Minimum Order Quantity1 Piece
Voltage TypeAC
Voltage (V)380 - 415 V
Number of Poles3 Pole, 4 Pole
ApplicationVoltage monitoring and output (contactor) feedback monitoring and protection
Current (Amps)8A @ 250V AC

RNPP-302 numeric voltage monitoring relay is designed for protection of three phase loads against major type of mains faults, as:


  • RMS voltage reaching beyond admissible thresholds - over and under voltage
  • Phase loss or Single phasing
  • Phase sequence order violation or reverse phase sequence
  • Phase coincidence or shorting of two or more phases
  • Phase Imbalance or asymmetry
  • Contactor output side monitoring - full phase switching, contactor health

 

The device performs monitoring the main circuit parameters and de-energizes (trips) load when the parameters fall beyond specified boundaries.

 

The three digit, seven segment LED display on the relay front panel allows to:


  • Continuously indicate the true RMS circuit voltage - phase voltage or line voltage
  • Indicate type of occurring fault
  • View (visualize) settings of modes and programming parameters

 

The menu allows the user to make the following settings:


  • Mode of voltage indication for each phase
  • Mode of the relay reaction to the digital input for remote de-energizing (tripping)
  • Type of relay - phase voltage or line voltage
  • Method for setting the voltage deviation
  • Turn on/off the phase imbalance monitoring
  • Turn on/off the phase sequence order monitoring
  • Contactor output terminals voltage monitoring
  • Type of measured voltage - 220/380 V, 230/400 V, 240/415 V
  • The maximum allowable voltage tripping threshold
  • The minimum allowable voltage tripping threshold
  • Allowable phase imbalance threshold - %
  • Automatic reset delay time
  • Min voltage de-energize (tripping) delay time
  • Max voltage de-energize (tripping) delay time
  • Phase imbalance tripping delay time
  • Phase loss tripping delay time
  • Delay time for tripping upon a digital input (external emergency button input)
  • Monitoring of full phase switching of contactor (output side monitoring)

 

The device is equipped with an additional alarm/annunciation relay with normally open contacts lead out.

 

Documentation for this device

Request
Callback


Additional Information:

  • Item Code: RNPP-302
  • Port of Dispatch: New Delhi
Yes! I am Interested
View PDF

Three Phase Voltage Monitoring Relays

Three Phase Voltage Monitoring Relays
  • Three Phase Voltage Monitoring Relays
Ask For Price

Product Details:

Voltage TypeAC
Voltage (V)415 V
Number of Poles3 Pole, 4 Pole
ApplicationThree Phase Voltage Mnitoring and Protection
Current (Amps)5A @ 250V AC

The RNPP-301 voltage monitoring relay is designed for protection of three-phase loads against major type of mains faults, as:

 

  • RMS voltage reaching beyond admissible thresholds
  • Phase sequence order violation and phase coincidence
  • Violation of the mains voltage phase completeness and symmetry

 

The device performs monitoring the main circuit parameters and de-energizes load when the parameters fall beyond specified boundaries. The relay also tracks the status of magnetic starter power contacts at no-load and under load while monitoring their operability (burning or sticking).

 

The front panel LEDs display the following:

 

  • Presence of voltage in the mains
  • Load status (ON/OFF)
  • Type of fault

 

Six variable pot knobs on the front panel allow for setting:

 

  • The maximum allowable voltage tripping threshold
  • The minimum allowable voltage tripping threshold
  • Allowable phase imbalance threshold
  • Tripping time delay for load de-energizing in case of emergency voltage reduction
  • Tripping time delay for load de-energizing in case of other circuit faults
  • Time delay for load re-energizing after the circuit parameters recovery

 

The device can function a phase- or line- voltage monitor (user-selected). Three modifications of this device are currently produced.

 

Documentation for this device

Request
Callback


Additional Information:

  • Item Code: RNPP-301
  • Port of Dispatch: New Delhi
Yes! I am Interested
View PDF

Three Phase Voltage Monitoring

Three Phase Voltage Monitoring
  • Three Phase Voltage Monitoring
Ask For Price

Product Details:

Voltage TypeAC
Voltage (V)400 - 415V AC
Number of Poles3 Pole, 4 Pole
ApplicationMains Voltage & Frequency Monitoring
Current (Amps)5A

Three Phase Relays For Monitoring Voltage, Phase Imbalance and Phase Sequence

The RNPP-311 voltage monitoring relay is designed for protection of three-phase loads against major type of mains faults, as:

 

  • RMS voltage reaching beyond admissible thresholds
  • Phase sequence order violation and phase coincidence
  • Violation of the mains voltage phase completeness and symmetry

 

The device performs monitoring the main circuit parameters and de-energizes load when the parameters fall beyond specified boundaries.

 

The front panel LEDs display the following:

 

  • Presence of voltage in each phase
  • Emergency de-energizing the load

 

The trip setting for the maximum/minimum voltage threshold is combined and is set by adjustable potentiometer as percentage of the rated voltage. RNPP-311 automatically energizes load upon expiration of the AR (automatic restart time) since the moment of the mains parameters recovery. The devices are manufactured with standard AR delay set to 5 sec, but optionally, they can be manufactured with the AR delay presets of 0, 10, 60, 100, 150, 200 and 250 sec.

 

Documentation for this device

Request
Callback


Additional Information:

  • Item Code: RNPP-311-1
  • Port of Dispatch: New Delhi
Yes! I am Interested
View PDF
X
Looking for “Three Phase Voltage Monitoring Relays”?


Reach Us
Debashish Ghosh (Director)
C - 30, Patparganj Industrial Area F.I.E.
Delhi -110092,India


Call Us

Send E-mail

Send SMS